The municipal water treatment plant or a seawater desalination facility contains hundreds of isolation and control valves, most of them between DN150 and DN1200. Almost every one of those large valves is a butterfly valve with pneumatic actuator.
Water systems operate at modest pressures, typically six to sixteen bar, but at very high flow rates. Butterfly valves provide a large open area with a short face-to-face length, so they fit into concrete chambers and skid frames where a gate or ball valve of the same bore cannot be installed. Their pressure drop is low, which directly reduces pumping energy, and pumping energy is the largest operating cost in any water plant.
| Stage | Typical Medium | Recommended Construction |
| Raw water intake | River or sea water, sand | Ductile iron body, epoxy coating, bronze or duplex disc, EPDM seat |
| Pre-treatment and filtration | Coagulated water, backwash | Ductile iron or stainless, EPDM seat |
| Reverse osmosis feed | Pressurised seawater | Super duplex or 316L, PTFE or EPDM seat, high-pressure rating |
| Brine and concentrate | High chloride, high TDS | Super duplex, duplex disc, PTFE seat |
| Sludge and dosing | Abrasive or chemical | Rubber-lined body, PTFE seat, corrosion-resistant disc |
| Permeate and potable water | Treated water | Epoxy-coated ductile iron, EPDM seat |
Corrosion, not pressure, destroys valves in desalination. Chloride levels above 20,000 mg per litre will attack 316 stainless steel, so super duplex are mandatory on the brine side, and the disc edge, which is the thinnest section, is usually the first place to fail.
Water valves foul. Biofilm, scale and grit accumulate on the disc and seat and gradually raise the operating torque. A well-specified actuator includes a torque margin of at least 50 percent above the clean-condition break torque, so that the valve still strokes when fouled. Seat replacement is the main wear task and should be possible without removing the valve from the line; a wafer design with a replaceable liner.
Pneumatic butterfly valves dominate water treatment and desalination because they combine large-diameter capacity, low pressure loss, fast and fail-safe actuation, and low installed cost. The engineering effort belongs in three places: alloy selection against chloride, actuator sizing against fouled torque, and a seat design that can be serviced in place.