Descriptions And Features Of UPVC Socket Double Union Pneumatic Ball Valve:
The pneumatic UPVC ball valve (double union type) is a corrosion-resistant plastic ball valve designed for pipelines conveying various corrosive fluid media. Its valve body is assembled from UPVC (CPVC) injection-molded components, exhibiting exceptional corrosion resistance. Operated by pneumatic pressure to control valve opening and closure, this configuration significantly reduces manual labor requirements and operational time, thereby substantially enhancing work efficiency.
The recommended medium temperature range for pneumatic plastic ball valves is typically between -20°C and 80°C, contingent upon material specifications, with a maximum working pressure not exceeding 1.0 MPa. It is not advisable to employ pneumatic plastic ball valves in pipelines containing hard particulate matter, as such particles may scratch the ball surface or sealing faces, potentially leading to leakage.
Design Features Of SONGO Pneumatic Actuator:
Part Material Of Pneumatic Actuated UPVC Socket type double Union Ball Valve:
| Connect Type | BSPT, BSPP, NPT Female Thread,socket |
| Working Pressure | PN1.0MPa |
| Brand | SONGO |
| Size | DN15-DN100 |
| Temperature | -20℃~+80℃ |
| Medium | Fresh water,sewage, sea water, air, steam, food, medicine, oils, acids, etc. |
| Body | PVDF, UPVC, CPVC, PPH |
| Ball | PVDF, UPVC, CPVC, PPH |
| Stem | SS304, SS316 |
| Seat | EPDM, FPM |
| Operated | Pneumatic Actuated |
| Actuator parts | Solenoid Valve , Limit Switch , Positioner , FRL |
| Actuator type | Double Action , Single Action (Spring Return) |
Structure Dimension Drawing Of Pneumatic Operated UPVC Sock double Union Ball Valve:
![]()
| Size | D | d | E | h | L | L3 | H | H1 | H2 | T | F | C | M | L1 | L2 | Pneumatic Actuator No. | |
| Thread | Socket | ||||||||||||||||
| 1/2" | 50.5 | 12.8 | 29 | 16 | 22.5 | 120 | 67 | 32 | 20 | 11 x 11 | 9 | 5.5 | ISO522 F03 | 150 | 72.5 | AT-52 | |
| 3/4" | 62.5 | 19 | 34 | 18 | 25 | 135 | 72 | 40 | 20 | 11 x 11 | 9 | 5.5 | ISO522 F03 | 150 | 72.5 | AT-52 | |
| 1" | 69 | 24.5 | 40 | 22 | 27.5 | 150 | 80 | 45 | 18 | 26 | 11 x 11 | 9 | 5.5 | ISO522 F03 | 150 | 72.5 | AT-52 |
| 1-1/4" | 82.5 | 30 | 45.5 | 25 | 31.5 | 167 | 89.5 | 54 | 18 | 26 | 11 x 11 | 14 | 6.5 | ISO522 F04 | 171 | 83 | AT-63 |
| 1-1/2" | 99 | 38 | 57.5 | 27 | 34 | 178 | 93 | 63 | 27 | 35 | 11 x 11 | 14 | 6.5 | ISO522 F05 | 171 | 83 | AT-63 |
| 2" | 122.6 | 49 | 70 | 31 | 38 | 204 | 111 | 73.5 | 27 | 35 | 11 x 11 | 14 | 6.5 | ISO522 F05 | 171 | 83 | AT-63 |
| 2-1/2" | 150 | 64 | 38 | 44.5 | 234 | 120.6 | 90 | 35 | 35 | 14 x 14 | 16 | 8.5 | ISO522 F07 | 186 | 95.5 | AT-75 | |
| 3" | 178.2 | 79 | 43 | 49 | 259 | 138.5 | 110 | 35 | 35 | 14 x 14 | 19 | 8.5 | ISO522 F07 | 206 | 103.5 | AT-83 | |
| 4" | 218.5 | 99 | 57 | 63.5 | 311 | 163.5 | 124 | 35 | 35 | 14 x 14 | 19 | 8.5 | ISO522 F07 | 265 | 108 | AT-92 | |
![]()
PVC PIPE Standard:
| PIPE STANDARD OF PVC PIPE | ||||
| Normal size | BS | ANSI | JIS | DIN |
| 1/2'' | 21.2 | 21.34 | 22.00 | 20 |
| 3/4'' | 26.6 | 26.67 | 26.00 | 25 |
| 1'' | 33.4 | 33.40 | 32.00 | 32 |
| 1-1/4'' | 42.1 | 42.16 | 38.00 | 40 |
| 1-1/2'' | 48.1 | 48.26 | 48.00 | 50 |
| 2'' | 60.2 | 60.28 | 60.00 | 63 |
| 2-1/2'' | 75.2 | 73.03 | 76.00 | 75 |
| 3'' | 88.7 | 88.90 | 89.00 | 90 |
| 4'' | 114.1 | 114.3 | 114 | 110 |
| 5'' | 140 | 141.3 | 140 | 140 |
| 6'' | 160 | 168.3 | 165 | 160 |
| 8'' | 225 | 219.1 | 216 | 200 |
| 10'' | 200 | 273.1 | 267 | 250 |
| 12'' | 315 | 223.9 | 318 | 300 |
Ball Valve Standard:
| Ball Valve Standard | ||||
| GB Standard | ASME Standard | JIS Standard | DIN Standard | |
| Design Standard | GB/T12237 | API608 | JIS BS5351 | DIN 3357 |
| Inspection Standard | GB/T13927 | API598 | JIS B2003 | EN 12266 |
| Face-to-Face Standard | GB/T12221 | ASME B16.10 | JIS B2002 | DIN 3202-F4 |
| Flange Standard | HG/T 20592, GB/T9113,EN 1092-1, JB/T79.1 |
ASME B16.5 | JIS B2220 | EN 1092-1 |
| Pressure-Temperature Standard |
GB/T 26640 | ASME B16.34 | ASME B16.34 | ASME B16.34 |
| Fire Safe Standard | API607/API 6FA | API607/API 6FA | API607/API 6FA | API607/API 6FA |
Matching Air Accessories Selection For Pneumatic Ball Valve:
![]()
Pneumatic Actuator Accessories Options :
| Pneumatic Actuator Accessories Options | ||
| Pneumatic Actuator Pisition | Applicable Connection Standard |
Pneumatic Actuator Accessories |
| Actuator Upper | VDI/VDE 3845 | ● Limit Switch Box ● Proximity Switch ● P/P Pneumatic Positioner ( Control Input Signal Is 0.20-1.03 Bar or 3-15 PSI ) ● E/P Electro Pneumatic Positioner ( Control Input Signal Is 4-20mA ) |
| Actuator Back | VDI/VDE 3845 | Non Explosion-proof Type ExmbIICT4 / EX d IIB T6 / EX d IIC T6 / EX ia IIC T6 Explosion-proof Type ● 3/2 Way Namur Solenoid Valve ( For Spring Return Actuator ) ● 5/2 Way Namur Solenoid Valve ( For Double Acting Actuator ) Air Filter Regulator |
| Actuator Bottom | ISO5211/DIN3337 | ● Declutchable Gear Box ● Ball Valve , Butterfly Valve , Plug Valve |
Single Acting & Double Acting Difference Of Pneumatic Actuator:
| Principle Of Single Acting Pneumatic Actuator (Spring Return) | |
| Counter - Clockwise | Clockwise |
|
Air to port A forces the pistons outwards, causing the springs to compress, The pinion turns counterclockwise while air is being exhausted from port B. Loss of air pressure on port A, the stored energy in the springs forces the pistons inwards. The pinion turns clockwise while air is being exhausted from port A. |
Air to port B forces the pistons outwards, causing the springs to compress, The pinion turns counterclockwise while air is being exhausted from port B. Loss of air pressure on port A, the stored energy in the springs forces the pistons inwards. The pinion turns clockwise while air is being exhausted from port A. |
| Principle Of Double Acting Pneumatic Actuator | |
| Counter - Clockwise | Clockwise |
|
Air to Port A forces the pistons outwards, causing the pinion to turn counterclockwise while the air is being exhausted from Port B. Air to Port B forces the pistons inwards, causing the pinion to turn clockwise while the air is being exhausted from Port A. |
Air to Port A forces the pistons outwards, causing the pinion to turn clockwise while the air is being exhausted from Port B.
|
Operating Type Selection Of Ball Valve:
![]()
Connect End Selection Of Pneumatic Ball Valve:
![]()
Flow Path Selection Of Pneumatic 3 Ways Ball Valve:
![]()
29 Years Valve Factory Founded In 1996:
![]()
Good Feedback From 12382 Clients:
![]()
No Worries After Buy Our Valves With Our Engineers:
![]()
Frequently Asked Questions: